Siemens wins First Bus charging maintenance contract

Siemens wins First Bus charging maintenance contract

Siemens will maintain around 1,000 charging points for First Bus. The five-year agreement includes remote diagnostics, preventative maintenance, onsite repairs, and replacement components across the operator’s UK charging infrastructure.


IN Brief:

  • The agreement covers approximately 1,000 direct current charging points across the UK.
  • Siemens will provide continuous remote support alongside scheduled maintenance and onsite intervention.
  • First Bus operates more than 1,500 zero-emission buses and provides third-party access to selected charging depots.

Siemens has secured a five-year maintenance agreement with First Bus covering approximately 1,000 direct current charging points across the UK, establishing long-term service arrangements for one of the country’s largest electric bus charging networks.

The contract encompasses round-the-clock remote support, proactive equipment monitoring, preventative servicing, onsite repairs, and the provision of replacement components. It will support a fleet comprising more than 1,500 zero-emission buses.

Siemens has an established relationship with First Bus through Heliox, the electric vehicle charging equipment manufacturer it acquired in 2024. Heliox previously supplied charging infrastructure for the operator’s electrification programmes in Glasgow, York, and Leicester.

As those installations have entered regular service, the availability of charging equipment has become increasingly integrated with the operator’s ability to maintain scheduled passenger transport services.

Bus depots must accommodate vehicles returning from service with varying battery states of charge and different departure times. Charging schedules are therefore determined by both the electricity available at the depot and the operational requirements of individual vehicles.

An equipment fault can interrupt that schedule even where sufficient electrical supply remains available elsewhere within the installation. The effect on fleet availability depends on the number of affected charging points, alternative charging capacity, and the time remaining before vehicles are required to return to service.

Direct current chargers contain power electronic conversion equipment, cooling systems, electrical protection, control electronics, and communications interfaces. These systems must operate together to regulate the electricity delivered to vehicle batteries.

Communication with the vehicle’s battery management system establishes the permissible voltage and current during a charging session. A fault affecting that exchange can interrupt charging without necessarily indicating a failure of the charger’s principal power conversion equipment.

Continuous remote monitoring can help distinguish between such communication issues and problems involving electrical protection, temperature management, or equipment availability. Diagnostic records also allow service teams to identify recurring faults that may otherwise be treated as separate incidents.

Remote intervention can resolve certain software or communications problems without requiring an engineer to attend the depot. Where physical repairs are necessary, earlier diagnosis can help technicians determine the replacement components, test equipment, and access arrangements required.

The preventative maintenance element of the agreement addresses degradation arising from repeated equipment operation. High-power charging connectors, contactors, cable assemblies, and cooling equipment can experience wear that influences their reliability over extended periods.

Maintenance requirements vary according to equipment architecture, operating conditions, and manufacturer instructions. Inspections must also account for electrical safety, particularly where conversion equipment contains components capable of retaining electrical energy after its external supply has been disconnected.

At larger depots, charger availability is influenced by the extent to which individual equipment items depend on common electrical infrastructure. A modular conversion system may allow one power module to be isolated while others continue operating, whereas a fault affecting a shared transformer or distribution assembly can interrupt a larger proportion of charging capacity.

Siemens’s agreement covers the charging equipment and associated service functions. The precise contractual boundaries between those responsibilities and the maintenance of wider depot electrical infrastructure have not been disclosed.

The scale of First Bus’s electrification programme increases the operational requirements associated with maintaining that infrastructure. FirstGroup’s latest half-year results identify four fully electrified depots and a further 20 that have been substantially electrified, with zero-emission vehicles representing approximately 28% of its fleet at the end of September.

Charging installations are also being used to serve customers beyond the bus operator’s own fleet. First Bus’s First Charge business provides third-party commercial vehicle operators with access to selected depots, with 14 locations opened to external vehicles by July.

Shared access increases the potential utilisation of charging equipment, but adds further variables to maintenance planning and electricity demand management. External vehicle charging must be accommodated alongside the energy requirements of buses operating scheduled passenger services.

First Bus has separately been exploring the flexibility available from its electrified depots through participation in Britain’s electricity balancing mechanism. Its Glasgow Caledonia trial expanded from 34 to 172 charging outlets in September, using energy management technology developed with Optimo Energy to coordinate vehicle requirements and electricity market opportunities.

That trial is separate from the Siemens maintenance agreement, although both depend on the availability of operational charging equipment and reliable communications between depot systems.

Maintaining a nationwide charging network of approximately 1,000 points requires coordinated deployment of service personnel, diagnostic systems, replacement parts, and equipment records. Scheduling that work around depot operations will remain necessary throughout the five-year agreement as the number of electric vehicles relying on the infrastructure continues to increase.


  • TotalEnergies completes Steeple solar and storage acquisition

    TotalEnergies completes Steeple solar and storage acquisition

    TotalEnergies has acquired a consented solar development incorporating battery storage. The Nottinghamshire project combines approximately 450 MW of planned solar export capacity with a 150 MW battery installation, utilising existing transmission infrastructure near West Burton.


  • Siemens wins First Bus charging maintenance contract

    Siemens wins First Bus charging maintenance contract

    Siemens will maintain around 1,000 charging points for First Bus. The five-year agreement includes remote diagnostics, preventative maintenance, onsite repairs, and replacement components across the operator’s UK charging infrastructure.